System self-test: Difference between revisions
Jump to navigation
Jump to search
m (Added Repairs category) |
mNo edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
=Cartridge systems= | =Cartridge systems= | ||
Some information by Channelmaniac. | |||
The AES home console only performs checks when no game is detected. | |||
{|class="regdef" | {|class="regdef" | ||
Line 41: | Line 43: | ||
==MVS checks== | ==MVS checks== | ||
Additionnal checks are performed on MVS systems: | Additionnal checks are performed on MVS systems. The SP-S2 [[system ROM]] does them in the following order: | ||
# Work RAM | |||
# Backup RAM | |||
# Palette RAM bank 0 | |||
# Palette RAM bank 1 | |||
# Low VRAM | |||
# High VRAM | |||
# RTC | |||
# System ROM checksum | |||
# Z80 | |||
{|class="regdef" | {|class="regdef" | ||
Line 65: | Line 77: | ||
When a MVS board is powered up without cartridges inserted, the border color around the edges of the crosshatch screen indicates the system ROM region: | When a MVS board is powered up without cartridges inserted, the border color around the edges of the crosshatch screen indicates the system ROM region: | ||
* Red: Japanese, SPJ2 | |||
* Cyan: USA, SPU2 | |||
* Blue: Korean/Spanish, SPS2 | |||
* Yellow: European | |||
* Green: 6 slot (ROM name ?) | * Green: 6 slot (ROM name ?) | ||
=UniBios tests= | =UniBios tests= |
Latest revision as of 05:23, 8 November 2018
Todo: Order of checks.
Cartridge systems
Some information by Channelmaniac.
The AES home console only performs checks when no game is detected.
Error | No game | WORK RAM ERROR | COLOR RAM ERROR | VIDEO RAM ERROR | SYSTEM ROM ERROR | MEMORY CARD ERROR |
AES | ||||||
MVS | Crosshatch | Screenshot needed | ||||
Meaning | All tests passed (AES does not test the Z80). Cartridge not detected. | 68k user RAM R/W error | Palette RAM R/W error | VRAM R/W error | System ROM checksum mismatch | Memory card R/W error (only tested if card present and blank) |
MVS checks
Additionnal checks are performed on MVS systems. The SP-S2 system ROM does them in the following order:
- Work RAM
- Backup RAM
- Palette RAM bank 0
- Palette RAM bank 1
- Low VRAM
- High VRAM
- RTC
- System ROM checksum
- Z80
Error | BACKUP RAM ERROR | Calendar freeze | CALENDAR ERROR | Z80 ERROR |
Display | ||||
Meaning | Backup RAM R/W error | RTC isn't giving Time Pulse | RTC ran to slow or too fast | Z80 didn't reply to command |
When a MVS board is powered up without cartridges inserted, the border color around the edges of the crosshatch screen indicates the system ROM region:
- Red: Japanese, SPJ2
- Cyan: USA, SPU2
- Blue: Korean/Spanish, SPS2
- Yellow: European
- Green: 6 slot (ROM name ?)
UniBios tests
The Universe BIOS does not use the above color codes to indicate errors.