Reset generator: Difference between revisions

From NeoGeo Development Wiki
Jump to navigation Jump to search
m (1 revision: Import from wikkii)
(→‎Replacement: Added a pin compatible replacement)
 
(6 intermediate revisions by one other user not shown)
Line 1: Line 1:
[[File:Cd1_resetgen.jpg|thumb|PST518B in a CD1 system.]]
[[File:Cd1_resetgen.jpg|thumb|PST518B in a CD1 system.]]


PST518B reset generator. Datasheet [[http://www.datasheetcatalog.org/datasheets/700/478877_DS.pdf here]].
The Mitsumi PST518B is a [[reset]] generator, it holds the NeoGeo in reset as long as the power supply is below 4.4V.
 
It has an open-collector output tied to the {{Sig|RST|RST}} line (not {{Sig|RESET|RESET}} !), which is shared with the reset button on the home system. The line goes to {{Chipname|NEO-B1}}.


Not to be confused with the [[watchdog]] reset.
Not to be confused with the [[watchdog]] reset.


[[Category:Base system]]
==Internal schematic==
 
[[File:Pst518b.png]]
 
Datasheet: [[File:PST518B.pdf]].
 
==Replacement==
 
Not pin-compatible: TL7757CL
 
Pin-compatible: MCP120-450GI/TO
 
 
[[Category:Chips]]

Latest revision as of 22:07, 13 June 2020

File:Cd1 resetgen.jpg
PST518B in a CD1 system.

The Mitsumi PST518B is a reset generator, it holds the NeoGeo in reset as long as the power supply is below 4.4V.

It has an open-collector output tied to the RST line (not RESET !), which is shared with the reset button on the home system. The line goes to NEO-B1.

Not to be confused with the watchdog reset.

Internal schematic

Datasheet: File:PST518B.pdf.

Replacement

Not pin-compatible: TL7757CL

Pin-compatible: MCP120-450GI/TO