Timer interrupt
Vector address on cartridge systems: $68. On CD systems: $64.
This interrupt can be used for scanline effects, it is triggered when the 32-bit down-counter internal to LSPC reaches 0. The value of this counter is decremented by the pixel clock (6MHz, every 166.7ns), and reloaded with the specified value in REG_TIMERHIGH and REG_TIMERLOW each time one of these 3 selectable events occur:
- Just when REG_TIMERLOW register is written to (immediately).
- At the beginning of the frame blanking period (one-shot).
- When the counter reaches 0 (repeat).
Like the others, this interrupt needs to be acknowledged to trigger again.
The REG_LSPCMODE register is used to configure the timer's operation:
- Bit 7 = 1: Load counter when it becomes 0.
- Bit 6 = 1: Load counter at the beginning of the hblank of the first vblank line.
- Bit 5 = 1: Load counter as soon as REG_TIMERLOW is written to.
- Bit 4 = 1: Enable timer interrupt.
If bit 5 is set, either bit 6, 7 or both must also be set to 1.
When the timer interrupt is enabled, the value of REG_TIMERHIGH and REG_TIMERLOW should always be set higher than 2, or it may lock the program.
To trigger interrupts for every N pixels, set the timer registers to N-1, and set bits 4 and 7 of REG_LSPCMODE.
To trigger interrupts when rendering reaches multiple arbitrary display locations, set bits 4, 5 and 7 of REG_LSPCMODE. Then, in the interrupt handler routine, set the interval between the next interrupt and the following in the timer registers.